Dental Hg FlexVac Air Purifier

Captures drill aerosols, abrasion powder and mercury vapors during dental procedures.
The Dental Hg FlexVac excels at capturing drill aerosols, abrasion powder and mercury vapors during dental procedures. The flexible suction duct is placed on the patient’s chest to directly capture aerosols and vapors before they become airborne.
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
Shipping Information
Use this text to answer questions in as much detail as possible for your customers.
Customer Support
Use this text to answer questions in as much detail as possible for your customers.
FAQ’s
Use this text to answer questions in as much detail as possible for your customers.
Contact Us
Use this text to answer questions in as much detail as possible for your customers.
Features

Extraoral Suction Meets Infection Control
The Dental Hg FlexVac is designed to capture airborne contaminants directly at the source during dental procedures. Positioned near the patient, the flexible suction duct helps prevent aerosols, particles, and vapors from dispersing into the surrounding environment.
Extraoral Suction for Infection Control
When combined with intraoral suction, the system can significantly reduce aerosol levels, bacterial colonies, and airborne viral particles generated during procedures.
Flexible Source Capture System
A semi-rigid, self-supporting duct with extended reach allows precise positioning, enabling effective capture exactly where contaminants are generated.

HyperHEPA Filtration Meets Mercury Vapor Control
The Dental Hg FlexVac is engineered to remove a wide range of airborne contaminants, including particles, biological agents, and hazardous vapors—supporting safer clinical environments.
HyperHEPA Filtration
Captures ultrafine particles, including bacteria and viruses, as well as dust and aerosolized contaminants generated during dental procedures.
Mercury Vapor Filtration
Specialized filtration media targets mercury vapor, along with gases, fumes, and odors commonly produced in dental settings.
Dental Procedure Aerosol Control
Designed to capture aerosols, particles, and mercury vapors directly at the source during dental procedures.
Semi-rigid suction duct allows precise positioning with extended reach for targeted aerosol capture.
Specialized filtration media helps reduce mercury vapor, gases, fumes, and odors generated during dental procedures.
Integrated mobility casters support flexible positioning and movement between treatment areas.
Filters ultrafine particles, including airborne bacteria and viruses, down to 0.003 microns.
Captures airborne contaminants near the patient before they disperse into the surrounding environment.
Dental HG FlexVac | Environmental control for dental offices
Technical Specifications
Air cleaning performance
Airflow, 6 fan speeds*:
per fan speed measured at 240V, 60 Hz; tolerance ± 10% (± 6 cfm)
Speed 1: 40 cfm | 70 m3h
Speed 2: 75 cfm | 130 m3h
Speed 3: 130 cfm | 220 m3h
Speed 4: 170 cfm | 290 m3h
Speed 5: 200 cfm | 340 m3h
Speed 6: 300 cfm | 510 m3h
General specifications
Dimensions:
varies (flexible suction duct)
Weight, system incl. filter:
Varies; min. 44 lbs. (20 kg)
Color of main housing / locking arms:
Light grey / white
Device control:
Control panel, remote control
Supplied accessories:
Remote control, power cord, casters, certificate of performance
Filters
Airborne Pollutants:Filters 95% particles ≥ 0.003 microns; extreme control of mercury and drilling aerosols; control of wide range of chemicals and odors at pollutant source
Average Filter Life*
H11 Pre-Filter: 13 months: 2 years and 5 months
Hg Cartridge:* 2 years and 5 months
GC Post-Filter Sleeves: 2 years and 5 months
Documents
FAQs
Dental Hg FlexVac Air Purifier
The Dental Hg FlexVac is designed to capture aerosols, particles, and mercury vapors generated during dental procedures. It helps reduce airborne contaminants directly at the source before they disperse into the surrounding environment.
The flexible suction duct is positioned near the patient to capture aerosols, vapors, and airborne particles during procedures. When combined with intraoral suction, it helps significantly reduce airborne contamination in treatment areas.
The system is engineered to help reduce drill aerosols, abrasion powder, mercury vapor, bacteria, viruses, gases, fumes, odors, and ultrafine airborne particles commonly generated in dental environments.
IQAir’s HyperHEPA technology is designed to filter ultrafine airborne particles down to 0.003 microns, including particles significantly smaller than those addressed by conventional HEPA filtration standards.
Yes. IQAir’s HyperHEPA filtration has been tested and proven to filter airborne biological contaminants, including bacteria and viruses in their airborne state.
The Dental Hg FlexVac includes specialized filtration media designed to help reduce mercury vapor and other gaseous contaminants generated during dental procedures.
Yes. The semi-rigid, self-supporting duct is designed for flexible positioning and extended reach, allowing source capture near the treatment area.
Yes. Integrated mobility casters allow the system to be repositioned between treatment rooms as needed.
The Dental Hg FlexVac is engineered for relatively quiet operation across fan speeds to help support more comfortable clinical environments.
The system is designed for dental offices, clinics, treatment rooms, and other environments where source capture and airborne contaminant control are important.
Talk to an Expert
Call 400-108-5117 to talk to an Indoor Air Quality (IAQ) Expert and explore options for your space.